The updated mode-matching solution to account for the noise eater alog(44783) assumed a waist at the coupler of 750um (because that was in the thorlabs documnentation recommended). However a measurement indicates a waist of 500um out of the coupler.
I adjusted the solution SHGtoFiberAM.pdf alog(44783) to move the ROC75 lens 6cm closer to the SHG the ROC200 lens 1-2 cm further away from the SHG and the fiber coupler 10 cm further away from the SHG to get a waist of 550um.
To get a waist of 500um would take a relatively major path rearrangement and with the vent only hours away it was a little risky to do it now, I will fine tune after the vent and hopefully the proper solution will be significantly above 85%.