https://ldas-jobs.ligo.caltech.edu/~gabriele.vajente/bruco_1226014475/
Thanks Gabriele, this will be useful. Just want to say for the record that the calibration was wrong during this time, we don't believe our sensitivity was really 100 Mpc.
Too bad, that would have been good. Nevertheless, the coherences are still significant and similar to what reported for earlier lock stretches.
The Pcal lines at the Y-end were turned on at ~1226014752.1 GPS sec (around 277.1 sec after the start of this bruco run) and there was no ramp up of the amplitudes of the lines. The high coherence we see around 30 Hz with PCal singal seems to come from sudden turn on of the lines and also due to spectral leakage. If I calculate the coherence for the first 270 secs or last 120 secs I don't see any such excess coherence.