BruCo scan for ~100 Mpc time

https://ldas-jobs.ligo.caltech.edu/~gabriele.vajente/bruco_1226014475/

 

 

 

Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 18:42, Monday 12 November 2018 (45244)

Thanks Gabriele, this will be useful.  Just want to say for the record that the calibration was wrong during this time, we don't believe our sensitivity was really 100 Mpc. 

gabriele.vajente@LIGO.ORG - 20:05, Monday 12 November 2018 (45245)

Too bad, that would have been good. Nevertheless, the coherences are still significant and similar to what reported for earlier lock stretches.

shivaraj.kandhasamy@LIGO.ORG - 10:20, Tuesday 13 November 2018 (45251)

The Pcal lines at the Y-end were turned on at ~1226014752.1 GPS sec (around 277.1 sec after the start of this bruco run) and there was no ramp up of the amplitudes of the lines. The high coherence we see around 30 Hz with PCal singal seems to come from sudden turn on of the lines and also due to spectral leakage. If I calculate the coherence for the first 270 secs or last  120 secs I don't see any such excess coherence.