edmond.merilh@LIGO.ORG - posted 15:18, Monday 12 November 2018 (45233)
PSL Weekly Status FAMIS #10986

Laser Status:
Front End Power is 0.01014W (should be around 30 W)
70W Output Power is 2.425W
Front End Watch is RED
70W Watch is GREEN

PMC:
It has been locked 0 days, 0 hr 0 minutes (should be days/weeks)
Reflected power = 0.0367Watts
Transmitted power = -0.0226Watts
PowerSum = 0.014Watts.

FSS:
It has been locked for 0 days 0 hr and 0 min (should be days/weeks)
TPD[V] = 0.04675V (min 0.9V)

ISS:
The diffracted power is around 0.14%
Last saturation event was 0 days 6 hours and 34 minutes ago (should be days/weeks)


Possible Issues:

Vent activities this week including but not limited to: Mode matching work, 70W amp remounting, plumbing work, and IO work

 