Jeff B. phoned me while I was doing this as he had noticed a very large spike in particulate in the Y-end VEA which exactly correlated with my having done this. Investigation revealed that the Y-end Turbo's local scroll pump never got a particulate filter installed at its exhaust - Ooops! -> I located this unit and will install it.
Also, the chilled water booster pump used with the QDP80 is now leaking at the pump end -> will put this on the list.
FRS ticket 11827
11/15/2018
I installed the particulate filter on the exhaust of the Y-end local scroll pump.