david.barker@LIGO.ORG - posted 16:23, Thursday 15 November 2018 (45318)
WP7946 Front end monit and ntp configuration

For all front end computers:

monit configuration was changed to allow workstations access to the web interface

ntp configuration was changed to write the drift file to /var/log/ (default was trying to write to a read-only file system)

To install it did the following:

1. restart monit to new configuration (/etc/init.d/monit restart)

2. Using firefox, go to the monit web page (http://name), go into ntp control page and press RESTART

Roughly an hour later, the /var/log/ntp.drift file was created, and the error message that it couldn't be created is no longer seen.