Displaying report 1-1 of 1.
Reports until 16:52, Thursday 25 October 2012
H2 CDS
david.barker@LIGO.ORG - posted 16:52, Thursday 25 October 2012 - last comment - 17:12, Thursday 25 October 2012(4530)
Dolphin install at EY completed

We configured h2boot's Dolphin master to control the three new Dolphin nodes at EY. We used the next three node ids in the sequence

h2pemey = 20

h2susb6 = 24

h2seib6 = 28

We tested by transitioning the IOP watchdog IPC from RFM to Dolphin (h2iopsusb6 sender, h2iopseib6 receiver).

Jeff then transitioned all IPC at EY from RFM to Dolphin for h2sustmsy, h2susetmy, h2isietmy, h2hpietmy, h2iscey and we power cycled the EY computers and restarted all models.

We hand editied the H2.ipc to remove the old RFM channels such that the names could be reused as Dolphin channels.

The IOP watchdog was retested. Jeff tested all SUS,SEI IPC.

Comments related to this report
jeffrey.kissel@LIGO.ORG - 17:12, Thursday 25 October 2012 (4532)
As of the above entry, I can confirm that the dolphin network communication between H2 ISI ETMY and its two SUS, H2 SUS ETMY and H2 SUS TMSY is functional, both on the sending (ISI GS13s to SUS, and SUS OFFLOAD to ISI) and receiving (of each) is functional. Further, the SUS PAYLOAD flag functionality from SUS to ISI is also functioning correctly.

This completes the installation of all changes from T1200478 (though the afore mentioned to do list remains -- I've been working on H1 today) I've again left ETMY and TMSY peacefully damped.