I tested different configurations of blend and isolation filters. To do so, I looked at the GS13 input in cartesian basis in the following configurations:
The blend filters used are the generic ("old" version) blend filters from SVN revision 6036.
Spectra are attached. Damping + Blend 500mHz + ISO level 1 et Damping + Blend 500mHz + ISO level 2 are not displayed to keep the plot readable. They are however saved under DTT.
I used the command window to switch between states. The Watchdogs (ISI,SUS,IOP) did not trip. Damping + Blend 250mHz + ISO level 2 was on for a couple hours without any WD trip. I then tested other configurations.
Comments on performace:
Damping + Blend 250mHz + ISO level 2 is currently running on HAM3-ISI