WHAM1 D6-1C Feed Thru Replaced

Per WP 7947 & II 4526, Corey and I replaced the 25p D-sub feed thru noted in the ticket and seen on D1002872 for ASC_REFL_A & B_WFS.

As an observation, the feed thru looks okay, testing TBD; but, both the in-air and in vac cable connections were poor with the in-vac connector a good 3/32" away from seating on the side of the conductors.  Both screws in this connector were tight indicating a cross thread condition and they were very rough/tight to unthread.  Maybe we need a bit of training to insure our connections are solid and sound.

Comments related to this report
corey.gray@LIGO.ORG - 12:51, Friday 16 November 2018 (45342)

Action shot of Hugh. 

Images attached to this comment
keita.kawabe@LIGO.ORG - 18:13, Friday 16 November 2018 (45353)

Relevant FRS that triggered this is: https://services.ligo-la.caltech.edu/FRS/show_bug.cgi?id=4526

After the flange swap, no clear improvement, but maybe something changed (that's in a sense worse than no change).

Attached is when ASC-REFL_A and B were illuminated using a flash light. Since one leg of differential output of ASC-REFL_A_DC_SEG4 was dead, we use a gain of 2 for this segment while others are 1.

If the problem was fixed (i.e. both of the differential output legs are functioning), I expect that A SEG4 output is twice as large as everything else. In reality it's somewhat larger than others (100 cts max VS 80) but not as twice as large, I don't think that it's fixed.

If this difference (100 VS 80) is real and is a result of the flange swap, though, this is a problem as it affects the centering. We'll see tomorrow by directing the beam to each segment one by one.

Another thing I noticed is that A SEG4 DC output is much noisier than others when dark (second attachment). The noise was worse before the flange swap and didn't change after, something I didn't pay attention before.

Images attached to this comment