CDS Dolphin driver upgrade: current status

WP7954

Jenne, Jonathan, Dave:

Today I recompiled all the models with the old driver to ensure that the models compile without errors. We found some new input ports needed connecting on h1susmc[1,2,3], which was fixed by Jenne. A new, clean H1.ipc file was then created and all the models compiled with zero errors. I verified that the SHMEM channels used by h1psliss were not changed, so we should not need to restart PSL models tomorrow.

I have put back the original H1.ipc file (called archive/H1.ipc.19nov2018) in case we have to restart models overnight. We will complete the install first thing tomorrow.