BSC1 ITMy Pitch/Yaw, Test Stand
D. Cook, J. Oberling
 
Measured pitch and yaw on the ITMy on the test stand this afternoon after SUS had performed adjustments.  As usual, yaw is reported assuming a top down view.
Comments related to this report
betsy.weaver@LIGO.ORG - 21:16, Monday 29 October 2012 (4546)

Note, prior to this set of measurements, I:

1) yawed the right side of R0 CW in order to alleviate the rubbing that the guys saw (and reported) last Friday. 

2) Then, I moved 100g of mass from the front to the back of the M0 UIM in an effort to correct some pitch that Jason observed.  I then recentered the pitch adjuster bars bringing the pitch error down to the number cited above.

3) Lastly, I yawed the M0 CW to reduce the yaw error to what Jason reports above.

BOSEMs need to be centered and then damping will hopefully work.