thomas.shaffer@LIGO.ORG - posted 18:22, Monday 19 November 2018 - last comment - 16:08, Wednesday 21 November 2018(45418)
HAM6 SUS TFs All Good

J. Kissel, T. Shaffer

All of the suspensions in HAM6 have been given the okay based on the ran transfer functions listed below. OM2 needed a cable to be repositioned by Hugh on the vacuum side of the feedthrough. These measurements still need to be processed in MatLab, but file names for the good measurements are listed below. These are located in the appropriate areas in the sus svn. They are the xml files for now (I incorrectly exported many of them so I will check on that tomorrow):

2018-11-19_2130_H1SUSOMC_M1_WhiteNoise_V_0p01to50Hz.xml
2018-11-19_2130_H1SUSOMC_M1_WhiteNoise_T_0p01to50Hz.xml
2018-11-19_2130_H1SUSOMC_M1_WhiteNoise_L_0p01to50Hz.xml
2018-11-19_2130_H1SUSOMC_M1_WhiteNoise_R_0p01to50Hz.xml
2018-11-19_2130_H1SUSOMC_M1_WhiteNoise_Y_0p01to50Hz.xml
2018-11-19_2130_H1SUSOMC_M1_WhiteNoise_P_0p01to50Hz.xml

2018-11-19_2130_H1SUSOPO_M1_WhiteNoise_Y_0p02to50Hz.xml
2018-11-19_2130_H1SUSOPO_M1_WhiteNoise_V_0p02to50Hz.xml
2018-11-19_2130_H1SUSOPO_M1_WhiteNoise_T_0p02to50Hz.xml
2018-11-19_2130_H1SUSOPO_M1_WhiteNoise_L_0p02to50Hz.xml
2018-11-19_2130_H1SUSOPO_M1_WhiteNoise_P_0p02to50Hz.xml
2018-11-19_2130_H1SUSOPO_M1_WhiteNoise_R_0p02to50Hz.xml

2018-11-19_2117_H1SUSOM1_M1_WhiteNoise_L_0p02to50Hz.xml
2018-11-19_2117_H1SUSOM1_M1_WhiteNoise_P_0p02to50Hz.xml
2018-11-19_2117_H1SUSOM1_M1_WhiteNoise_Y_0p02to50Hz.xml

2018-11-20_0025_H1SUSOM2_M1_WhiteNoise_L_0p02to50Hz.xml
2018-11-20_0025_H1SUSOM2_M1_WhiteNoise_P_0p02to50Hz.xml
2018-11-20_0025_H1SUSOM2_M1_WhiteNoise_Y_0p02to50Hz.xml

2018-11-19_2149_H1SUSOM3_M1_WhiteNoise_L_0p02to50Hz.xml
2018-11-19_2149_H1SUSOM3_M1_WhiteNoise_Y_0p02to50Hz.xml
2018-11-19_2149_H1SUSOM3_M1_WhiteNoise_P_0p02to50Hz.xml

2018-11-12_1849_H1SUSZM1_M1_WhiteNoise_L_0p02to50Hz.xml
2018-11-12_1849_H1SUSZM1_M1_WhiteNoise_Y_0p02to50Hz.xml

 

Comments related to this report
thomas.shaffer@LIGO.ORG - 16:08, Wednesday 21 November 2018 (45458)

See alog45456 for the processed results.