jason.oberling@LIGO.ORG - posted 16:05, Monday 29 October 2012 - last comment - 21:16, Monday 29 October 2012(4544)
BSC1 ITMy Pitch/Yaw, Test Stand
D. Cook, J. Oberling
Measured pitch and yaw on the ITMy on the test stand this afternoon after SUS had performed adjustments. As usual, yaw is reported assuming a top down view.
Pitch: ~750 µrad up
Target pitch: 12.5 µrad up
Yaw: ~185 µrad CCW
Target yaw: 0.0 µrad
Comments related to this report
betsy.weaver@LIGO.ORG - 21:16, Monday 29 October 2012 (4546)
1) yawed the right side of R0 CW in order to alleviate the rubbing that the guys saw (and reported) last Friday.
2) Then, I moved 100g of mass from the front to the back of the M0 UIM in an effort to correct some pitch that Jason observed. I then recentered the pitch adjuster bars bringing the pitch error down to the number cited above.
3) Lastly, I yawed the M0 CW to reduce the yaw error to what Jason reports above.
BOSEMs need to be centered and then damping will hopefully work.
Note, prior to this set of measurements, I:
1) yawed the right side of R0 CW in order to alleviate the rubbing that the guys saw (and reported) last Friday.
2) Then, I moved 100g of mass from the front to the back of the M0 UIM in an effort to correct some pitch that Jason observed. I then recentered the pitch adjuster bars bringing the pitch error down to the number cited above.
3) Lastly, I yawed the M0 CW to reduce the yaw error to what Jason reports above.
BOSEMs need to be centered and then damping will hopefully work.