EX had a Dolphin glitch overnight. Peter is on site for a PSL issue, I'm starting the EX recovery remotely from home.
I gathered all log and proc files and then restarted all models on h1seiex, h1susex and h1iscex by running /etc/startWorld.sh.
I have reset all the software watchdogs on h1susex and h1seiex and cleared all DIAGs and CRCs
EX is now ready to be driven.
Time of this Dolphin crash (local time):
Nov 25 2018 05:50:18 PST
Would the first commissioner in the control room please call my cell phone so we can complete the recovery of EX.
A verbal alarm stating an earthquake was detected(?) just came in. The plot in the Control Room is about to cross the 1 um/s level. Things might be rung up for a while.
Opened FRS-11873
Dan is completing the EX recovery from the control room.