david.barker@LIGO.ORG - posted 08:25, Sunday 25 November 2018 - last comment - 13:40, Sunday 25 November 2018(45482)
EX Dolphin glitch

EX had a Dolphin glitch overnight. Peter is on site for a PSL issue, I'm starting the EX recovery remotely from home.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 08:50, Sunday 25 November 2018 (45485)

I gathered all log and proc files and then restarted all models on h1seiex, h1susex and h1iscex by running /etc/startWorld.sh.

I have reset all the software watchdogs on h1susex and h1seiex and cleared all DIAGs and CRCs

EX is now ready to be driven.

david.barker@LIGO.ORG - 08:57, Sunday 25 November 2018 (45486)

Time of this Dolphin crash (local time):

Nov 25 2018 05:50:18 PST

david.barker@LIGO.ORG - 09:05, Sunday 25 November 2018 (45487)

Would the first commissioner in the control room please call my cell phone so we can complete the recovery of EX.

peter.king@LIGO.ORG - 09:36, Sunday 25 November 2018 (45489)
A verbal alarm stating an earthquake was detected(?) just came in.  The plot in the Control Room
is about to cross the 1 um/s level.  Things might be rung up for a while.
david.barker@LIGO.ORG - 13:17, Sunday 25 November 2018 (45490)

Opened FRS-11873

david.barker@LIGO.ORG - 13:40, Sunday 25 November 2018 (45491)

Dan is completing the EX recovery from the control room.