IO lens L1 replaced, IMC relocked

I replaced the IO lens, L1, that's downstream of the EOM by about 3 inches.  The new lens needed to shift +Y direction from the old lens, to recover yaw, and recovery of the IMC WFS with an unlocked IMC revealed that the IMC_IN beam was still off in yaw, so I also made a very small adjustment with M3, unnoticeable on the rotation stage, and the iris, but seen by the cameras and IMC.

I realigned the IMC, and relocked, and checked against previous locks.  My target lock was the Nov 26, 17:00 lock, and current values for the IMC mirrors are within -15.7urad to +10.9urad from the target.   H1:IMC-REFL_DC_OUT16 is now at 0.072.

  Nov 26 Nov 28 diff
  17:00 07:42  
lens change before after  
       
       
'H1:SUS-MC1_M3_WIT_PMON' -275.9 -272.0 3.9
'H1:SUS-MC1_M3_WIT_YMON' -983.1 -972.3 10.9
'H1:SUS-MC2_M3_WIT_PMON' 156.2 140.5 -15.7
'H1:SUS-MC2_M3_WIT_YMON' 627.2 630.7 3.5
'H1:SUS-MC3_M3_WIT_PMON' -685.6 -675.6 10.0
'H1:SUS-MC3_M3_WIT_YMON' -1255.8 -1260.6 -4.8