Front end systems look good this morning. The only item to note is that h1sush56 detected Dolphin IPC errors from h1lsc0 and h1sush34 early this morning. These errors then propagated down the chain to the IOP models of h1seih16 and h1sieh45. The attached images show the IPC status for h1susomc, h1sussrm, h1sussr3 (on h1sush56), h1iopseih16 and h1iopseih45. The IPC overview medm is also shown.
All the events happened at GPS 1227774329 which is Dec 02 2018 00:25:11 PST
I have captured the Dolphin dis_diag stats, nothing of note since yesterday morning.
Scans of front end logs and dolphin stats are run as user controls on h1build, and write their results to the /opt/rtcds/lho/h1/log/h1build/[full, dolphin] directories. Within each directory a 'current' symbolic link points to the most recent data.