Displaying report 1-1 of 1.
Reports until 11:32, Monday 03 December 2018
H1 IOO (IOO)
cheryl.vorvick@LIGO.ORG - posted 11:32, Monday 03 December 2018 (45643)
IM4 Trans changes since last week
  
11/25, 5:00 UTC
11/26, 17:50 UTC 11/27, 23:00 UTC 11/28, 1:45 UTC 12/3, 19:00 UTC
IM4 TRANS Pitch -0.030 -0.016 0.230 0.030 0.205
IM4 TRANS Yaw -0.184 -0.174 0.147 -0.020 0.149
     
After L1
lens swap
IM1 and IM2 changed to
center on IM4 TRANS
IM1 and IM2 restored to
historical values

 

change  11/26 11/27, pre, post, L1 swap diff
IM4 TRANS Pitch 0.246
IM4 TRANS Yaw 0.321
1) Changes of 0.23 to 0.32 on IM4 TRANS QPD are large, and will be seen in the IFO
2) The IMC beam spot measurement script (setting P2L and Y2L gains) is being run today if/when the IFO breaks lock
           a) this will tell me how much the beam changed at IM1, a change that is then propagated through the IO system and into the IFO
Displaying report 1-1 of 1.