chandra.romel@LIGO.ORG - posted 11:34, Monday 03 December 2018 - last comment - 17:32, Monday 03 December 2018(45642)
RGA data before & after valving in two corner NEG pumps

RGA text file attached with scans before-during-after valving in last two NEG pumps in corner station (NEGs within several feet of RGA). Gerardo will note the times that he valved in each pump in order to correspond to RGA scans. We were looking for changes in H2 partial pressure but didn't see much change by simply eye-balling the RGA scan; attached is PDF of scan after pumps valved in - H2 partial pressure was at ~ 1e-7 A before and after.

Non-image files attached to this report
Comments related to this report
gerardo.moreno@LIGO.ORG - 12:09, Monday 03 December 2018 (45644)VE

NEG2 and NEG1 valved in around 18:52 utc, and NEG2 was valved in first.

gerardo.moreno@LIGO.ORG - 17:32, Monday 03 December 2018 (45662)VE

Plot comparing LVEA RGA scans before and after the NEG pumps were valved in.