Because it looks (from my remote connection) like data from the H1 SUS PR2 (and H1 SUS MC2, probably more) has frozen, and anticipating a bootfest, I've taken (and svn committed) a new 
${userapps}/sus/h1/burtfiles/pr2/h1suspr2_safe.snap
to absorb all the new features and EPICs values I've been entering in. I've checked, and there is an approriate softlink in 
/opt/rtcds/lho/h1/target/h1suspr2/h1suspr2epics/burt/safe.snap
and checked that it works by changing a few things, and restoring to it.
The file was captured "by hand" using the command
pr2 0$ burtrb -f /opt/rtcds/lho/h1/target/h1suspr2/h1suspr2epics/autoBurt.req > /opt/rtcds/userapps/release/sus/h1/burtfiles/pr2/h1suspr2_safe.snap 
... but if LLO has a script for this, that'd be great to have ...
(and as I was writing this entry, I saw that someone had rebooted H1 SUS PR2. *phew*).