jeffrey.kissel@LIGO.ORG - posted 15:55, Monday 03 December 2018 (45654)
PCAL MASTER Front-end Model Bug Fixes
S. Karki, J. Kissel

As sudarshan pointed out last week (see LHO aLOG 45587), there were some bugs / inconsistencies between the recent front-end implementation of the explicit calculation of the PCAL optical efficiencies and force coefficients (calculations described in the appendix of T1800046; implemented in LHO aLOG 44418).

I've fixed the model (new screen shots attached), and have restarted the front-end code for both h1calex and h1caley, both of which use the library part I changed, 
    /opt/rtcds/userapps/release/cal/common/models/PCAL_MASTER.mdl
which has been committed to the repo.

The updated screen is also attached, and committed to
    /opt/rtcds/userapps/release/cal/common/medm/PCAL_END_FORCE_COEFF.adl