Danny, Dan
There is a weak point absorber on ETMX we saw in the 20W power up today. This seems significantly weaker than the current ITMY absorbers. The first image shows the point absorber and ifo beam heating, the cross marks the center of the beam heating. By choosing a reference 350s later over the same timeframe we can extract the ifo beam heating only, as shown in the second image.