Displaying report 1-1 of 1.
Reports until 11:51, Saturday 08 December 2018
H1 SQZ (SQZ)
nutsinee.kijbunchoo@LIGO.ORG - posted 11:51, Saturday 08 December 2018 - last comment - 18:15, Sunday 09 December 2018(45774)
SQZ intensity noise at various places

Daniel, Nutsinee

Attached a RIN plot of various detectors on ISCT6 table. The blue plot is the intensity noise measured off the laser monitor diode. By the time we get to SHG trans PD the noise is worsen by a factor of 10 at ~2-3kHz. The factor of two difference between SHG trans (red) and the green PDs is due to red->green conversion. Question is, this is what we saw in the IFO squeezing attempt in alog45767 ?   To be sure that switching scheme helps we need the same intensity noise data from LLO to compare. If LLO intensity noise is not as bad as ours switching scheme may not solve the problem. 

 

Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 18:15, Sunday 09 December 2018 (45787)

Terry, Sheila

We looked at coherence between DARM when we had injected squeezing on Friday night, with intensity noise on a few of the diodes which are recorded at 2kHz.  (OPO REFL, SHG trans, and CLF refl).  We don't see any coherence with intensity noise and DARM.  

We also looked at the additive offset channel which was used to detune the OPO from resonance, and we don't see any coherence with DARM. 

We wouldn't expect a linear coupling from either of these things to DARM in the first place, unless we have a bad seeding problem, but this was just a check.  We will work on setting up a diode to test for seeding.   

 

Images attached to this comment
Displaying report 1-1 of 1.