hang.yu@LIGO.ORG - posted 17:43, Saturday 08 December 2018 - last comment - 10:07, Monday 10 December 2018(45779)
Locklosses after ~15 mins at 28 W

Stefan, TVo, Hang

We were able to power up to 28 W and stay there stably for about 15 mins or so. However, after that we still had two kinds of locklosses.

=======================================

In the first time we lost lock when POP18 dropped to 50 and then a fast lock loss. Since we had re-distributed the gains in the common mode board (as powering up, in stead of dropping gains at the very end using IMC-REFL_SERVO_FASTGAIN, we decreased the gain upstream in LSC-REFL_SUM_A_IN2GAIN), this thus ruled out that saturation inside the common mode board was the cause for the fast lock losses. More investigation needed.

Also we noticed that at 20 W the LSC-REFL_A_RF9_Q was very close to zero, meaning a good balance of the upper and lower sidebands, while as we powering up, the REFL_9_Q increased by a lot.

=======================================

In the second time, still after about 15 mins at 28 W, an oscillation at 0.4 Hz grew in CHARD YAW ASC. This might be related to the CHARD blending (for yaw, DC part from REFL 9 and AC part from TR QPD combo) which was designed to happen at 0.4 Hz. As we kept losing optical response in the REFL9 signal, this might then lead to an instability in the signal blending. This hypothesis is also consistent with the fact that we did not see similar behavior in CHARD PITCH, as we changed the input matrix for CHARD PIT DC path to REFL45 (LHO:43633) which decayed much less then the RF9 signal and therefor the pitch stayed stable. The solution might thus be either changing the CHARD YAW to using REFL 45 like we did for pitch, or monitoring the signal strength in both REFL9 and QPD combo to keep their ratio constant, or (for a single lock) servo CHARD YAW only to QPD combos as a quick test.

Comments related to this report
stefan.ballmer@LIGO.ORG - 17:45, Saturday 08 December 2018 (45780)

Here is a plot of what LSC REFL does when going to 30W. THe growth in the final 50 seconds corresponds to the 0.4Hz instability.

Images attached to this comment
thomas.vo@LIGO.ORG - 10:07, Monday 10 December 2018 (45811)

We also tried a common lens adjusted on the CO2 lasers to try and re-gain some POP18 build up but we couldn't get back much (about 2 counts) compared to the drop from about 70 to 55 counts.  Two caveats though, we only waited about 5 minutes before moving on so maybe it would have gotten better and also the REFL9_Q_ERR seems to get noisier going from 20 watts to 25 watts which could get better with differential lens tuning.

Displaying report 1-1 of 1.