david.barker@LIGO.ORG - posted 16:31, Monday 10 December 2018 (45824)
h1tcscs EPICS input mechanism changed, ring heater inverse filtered by model

WP7997: inverse ring heater filters added to h1tcscs, output sent to Beckhoff

WP7996: replace model ezca(read,write) parts with EPICS parts, CDS_CA_COPY guardian node handles data transfer

Danni, TJ, Dave:

h1tcscs model was changed to:

replace all existing EzCaRead parts with EpicsIn parts

add two filters for ITMY_RH_[UPPER,LOWER]_INVERSE_FILTER

send the output of the two new filters to EpicsOut parts

See attachment for simulink model details.

TJ created a new Guardian node called CDS_CA_COPY which will handle all EPICS Channel Access copies between front end models and slow controls IOCs.

The initial CDS_CA_COPY is just copying the input SET channels to h1tcscs. We will expand it to other copies later, including replacing the current camera_copy script.

The Guardian MEDM and the new H1CDS_CA_COPY_CUST.adl are shown in attachments. The latter is accessed via SITEMAP->CDS

Images attached to this report