Displaying report 1-1 of 1.
Reports until 10:02, Tuesday 11 December 2018
H1 PSL (PSL)
corey.gray@LIGO.ORG - posted 10:02, Tuesday 11 December 2018 (45836)
PSL Weekly Report (FAMIS #10990)

Laser Status:
Front End Power is 32.61W (should be around 30 W)
70W Output Power is 71.3W
Front End Watch is RED
70W Watch is GREEN

PMC:
It has been locked 2 days, 17 hr 3 minutes (should be days/weeks)
Reflected power = 13.38Watts
Transmitted power = 51.76Watts
PowerSum = 65.15Watts.

FSS:
It has been locked for 0 days 1 hr and 19 min (should be days/weeks)
TPD[V] = 3.522V (min 0.9V)

ISS:
The diffracted power is around 2.8%
Last saturation event was 0 days 0 hours and 29 minutes ago (should be days/weeks)
Possible Issues:  No issues to report.