Displaying report 1-1 of 1.
Reports until 14:09, Tuesday 11 December 2018
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 14:09, Tuesday 11 December 2018 (45844)
CDS Maintenance Summary: Tuesday 11th December 2018

WP7984 h1lsc add fast channel

Daniel, Dave:

a new h1lsc model was installed, adding a missing 16k channel to the DAQ.

WP7995 OMC drumhead beason alignment

Keita, Dave:

New h1omc and h1omcpi models were installed.

WP8003 HAM6 Septum Accelerometer

Richard, Dave:

h1pemcs model was changed to add H1:PEM-CS_ACC_HAM6VAC_SEPTUM_Y (acquired at 4kHz). We are using the 11th channel of the 6th ADC.

WP8002 Fader code debugging, temporary add ISI ETMY fast to DAQ

T.J. Dave:

h1isietmy model was changed to add two temporary fast channels for debugging.

Beckhoff SQZ code change:

Daniel, Patrick, Dave:

h1ecatc1plc4 code was changed, and new DAQ INI file was created.

DAQ Restart:

Dave

DAQ was restarted at 13:25 for new h1lsc, h1omc, h1omcpi, h1pemcs, h1isietmy, h1ecatc1plc4 code.