J. Kissel, T. Vo, H. Yu, K. Kawabe, C. Vorvick, D. VanderHyde Hang got us through low noise ASC, and we pushed through switching to low noise ETMX and into nominal low noise for the first time in DAYS. Hooorrrrray!! As we were reconciling all SDFs for all models against their OBSERVE files (which we were able to do and we blindly accepted everything), and clearing guardian nodes, in order to got to OBSERVING mode, the wind decided to pick up to 40 mph, and we lost lock. 10 minutes at ~75 Mpc...
We had to adjust a few things in guardian nodes -- namely change some nominal states: LASER_POWER from 30W to 20 W VIOLIN_DAMPING from IDLE to DAMPING_ON_DC LOCKLOSS_SHUTTER_CHECK from HIGH_ARM_POWER to LOW_ARM_POWER and we had a few of the old SPM differences on the ITMs causing warnings on the RX / RY ST2 tramps. We also had to add the ISC_LOCK guardian node to the "ignore" list /opt/rtcds/userapps/release/sys/h1/guardian/IFO_NODE_LIST.py because it was getting a notification that IMC_LOCK had a notification, which we know is because the IMC WFS are not centered -- a problem we will not fix during this run.There was a huge hump at around 30-40Hz in DARM which came from DHARD_Y during that 75Mpc time.
This was because EXLP_LBW filter in DHARD_Y (FM2) was not enabled before going into nominal low noise (due to manual operation error).
Next time it's locked in nominal low noise this will be enabled by the guardian, SDF will complain (because no-FM2 configuration was accepted), so you need to accept that again. It's also be a good idea to run a2l.