Reports until 12:44, Wednesday 19 December 2018
H1 CDS (DAQ, TCS)
david.barker@LIGO.ORG - posted 12:44, Wednesday 19 December 2018 - last comment - 12:46, Wednesday 19 December 2018(46074)
h1tcscs model updated, DAQ restarted

TiVo, Danni, Dave:

Two changes to h1tcscs: added RH_INVERSE filters for etmx and etmy, removed surplus 'ezca' parts for LSRPWR_MTR and replaced them with a connection between the ITM[X,Y] blocks and the SIM block.

DAQ was restarted.

Comments related to this report
david.barker@LIGO.ORG - 12:46, Wednesday 19 December 2018 (46075)

T.J., Dave:

The CDS_CA_COPY guardian node did not fail in the way we hoped when the LSRPWR_MTR channels were removed from h1tcscs, resulting the camera-copy part no longer running. We may need to split the node out into two.