Reports until 18:48, Wednesday 19 December 2018
H1 ISC (ISC)
craig.cahillane@LIGO.ORG - posted 18:48, Wednesday 19 December 2018 - last comment - 07:45, Thursday 20 December 2018(46082)
Scripts to run PRCL and SRCL lines using the LSC OSC matrix
If you want to monitor the PRCL and SRCL optical gain, you may run 

python /ligo/home/craig.cahillane/Git/IFO/LSC/scripts/PRCL_132HzLine_and_OscillatorMon.py
python /ligo/home/craig.cahillane/Git/IFO/LSC/scripts/PRCL_152HzLine_and_OscillatorMon.py
or
python /ligo/home/craig.cahillane/Git/IFO/LSC/scripts/SRCL_138HzLine_and_OscillatorMon.py
 
to start lines in the LSC oscillator matrices 1 and 2 respectively.  
The lines are demodulated at the correct phases for 20 watts, and the script sets the filter modules with 10 Hz bandpasses about the exc frequency, and a 0.1 lowpass on the I and Q signals.

An example PRCL optical gain monitor is shown below.  The POP 9 I signal is sent to H1:LSC-LOCKIN_1_DEMOD_1_SIG, demodulated by the excitation, and the results lowpassed and reported in H1:LSC-LOCKIN_1_DEMOD_1_{I,Q}_OUTPUT.

EDIT:
I made a MICH equivalent script in the same directory, and a bash script which launches all the OSCs: 

bash /opt/rtcds/userapps/release/lsc/h1/scripts/set_up_LSC_dither_lines.sh

and a code which shuts down the dither lines:

bash /opt/rtcds/userapps/release/lsc/h1/scripts/take_down_LSC_dither_lines.sh
Images attached to this report
Comments related to this report
rana.adhikari@LIGO.ORG - 02:12, Thursday 20 December 2018 (46087)

Several times during the power ups tonight, we ran 4 lines in yaw to measure the changes in the ASC yaw sensing matrix:

PRC1   H1:ASC-ADS_YAW1_OSC_FREQ       16.131
PRC2   H1:ASC-ADS_YAW2_OSC_FREQ       18.37
CHARD  H1:ASC-ADS_YAW8_OSC_FREQ       23.25
CSOFT  H1:ASC-ADS_YAW9_OSC_FREQ       21.111

analysis in progress...

craig.cahillane@LIGO.ORG - 07:45, Thursday 20 December 2018 (46092)
According to our last lock this evening our POP9I/PRCL optical gain fell by a factor of 5 during the entire thermalization.  Dan was playing around with ring heaters, which caused the drop at end, but overall this is pretty dire.

POP45I/SRCL fell by ~15% in the same time.  POP45Q/MICH did not move much, with only about a 5% drop.
Images attached to this comment