Scripts to run PRCL and SRCL lines using the LSC OSC matrix
If you want to monitor the PRCL and SRCL optical gain, you may run 

python /ligo/home/craig.cahillane/Git/IFO/LSC/scripts/PRCL_132HzLine_and_OscillatorMon.py
python /ligo/home/craig.cahillane/Git/IFO/LSC/scripts/PRCL_152HzLine_and_OscillatorMon.py
or
python /ligo/home/craig.cahillane/Git/IFO/LSC/scripts/SRCL_138HzLine_and_OscillatorMon.py
 
to start lines in the LSC oscillator matrices 1 and 2 respectively.  
The lines are demodulated at the correct phases for 20 watts, and the script sets the filter modules with 10 Hz bandpasses about the exc frequency, and a 0.1 lowpass on the I and Q signals.

An example PRCL optical gain monitor is shown below.  The POP 9 I signal is sent to H1:LSC-LOCKIN_1_DEMOD_1_SIG, demodulated by the excitation, and the results lowpassed and reported in H1:LSC-LOCKIN_1_DEMOD_1_{I,Q}_OUTPUT.

EDIT:
I made a MICH equivalent script in the same directory, and a bash script which launches all the OSCs: 

bash /opt/rtcds/userapps/release/lsc/h1/scripts/set_up_LSC_dither_lines.sh

and a code which shuts down the dither lines:

bash /opt/rtcds/userapps/release/lsc/h1/scripts/take_down_LSC_dither_lines.sh
Images attached to this report
Comments related to this report
rana.adhikari@LIGO.ORG - 02:12, Thursday 20 December 2018 (46087)

Several times during the power ups tonight, we ran 4 lines in yaw to measure the changes in the ASC yaw sensing matrix:

PRC1   H1:ASC-ADS_YAW1_OSC_FREQ       16.131
PRC2   H1:ASC-ADS_YAW2_OSC_FREQ       18.37
CHARD  H1:ASC-ADS_YAW8_OSC_FREQ       23.25
CSOFT  H1:ASC-ADS_YAW9_OSC_FREQ       21.111

analysis in progress...

craig.cahillane@LIGO.ORG - 07:45, Thursday 20 December 2018 (46092)
According to our last lock this evening our POP9I/PRCL optical gain fell by a factor of 5 during the entire thermalization.  Dan was playing around with ring heaters, which caused the drop at end, but overall this is pretty dire.

POP45I/SRCL fell by ~15% in the same time.  POP45Q/MICH did not move much, with only about a 5% drop.