Displaying report 1-1 of 1.
Reports until 12:35, Thursday 20 December 2018
H1 SUS (ISC)
richard.mccarthy@LIGO.ORG - posted 12:35, Thursday 20 December 2018 - last comment - 16:21, Thursday 20 December 2018(46103)
H1 EX EY Power Supply

Following Robert's post about fan lines in the Darm spectrum from EX Fil and I went down and investigated cabling.  I did not like the grounding scheme on the new +-18/48VDC power supplies so we changed the connection.  The supplies are now hard wired together through the returns and grounded.  Other supplies are done this way but they only supply 2 voltages not 4.  Will look for improvement or not.

Comments related to this report
filiberto.clara@LIGO.ORG - 16:21, Thursday 20 December 2018 (46110)

EY grounding scheme was also changed.