EY has had a Dolphin crash. I'm restarting the models.
I've opened FRS12076
I took dolphin diagnostics before restarting. comparing Sat 5 Jan with Tue 25 Dec scans shows that an error appeared on h1iscey in this case.
## h1iscey ##################################################### 8c8 < Date : Sat Jan 5 21:39:45 PST 2019 --- > Date : Tue Dec 25 10:07:36 PST 2018 44c44 < Link 0 uptime : 3982458 seconds --- > Link 0 uptime : 2995486 seconds 56c56 < Chip temperature : 77 C --- > Chip temperature : 75 C 102,135d101 < **************** PCIe SLOT ERROR INFORMATION FOR ADAPTER NO 0 **************** < < NACK error cnt - PCIe Slot .................... : 1 < NACK DLLP transmitted ......................: 1 < NACK DLLP received .........................: 0 < < Total uncorrectable error cnt - PCIe Slot ..... : 0 < dlperr cnt ................................ : 0 < sdoenerr cnt .............................. : 0 < poisoned cnt .............................. : 0 < fcperr cnt ................................ : 0 < compto cnt ................................ : 0 < cabort cnt ................................ : 0 < uecomp cnt ................................ : 0 < rcvovr cnt ................................ : 0 < malformed cnt ............................. : 0 < ecrc_cnt .................................. : 0 < ur_cnt .................................... : 0 < acsv_cnt .................................. : 0 < uie_cnt ................................... : 0 < mcblktlp cnt .............................. : 0 < atopeb cnt ................................ : 0 < tlppbe cnt ................................ : 0 < < Total correctable error cnt - PCIe Slot ....... : 1 < rcverr cnt ................................ : 1 < badtlp cnt ................................ : 1 < baddllp cnt ............................... : 1 < rplyrovr cnt .............................. : 0 < rplyto cnt ................................ : 0 < advisorynf cnt ............................ : 0 < cie cnt ................................... : 0 < hlo cnt ................................... : 0 <