Displaying report 1-1 of 1.
Reports until 21:38, Saturday 05 January 2019
H1 CDS
david.barker@LIGO.ORG - posted 21:38, Saturday 05 January 2019 - last comment - 11:32, Monday 07 January 2019(46249)
EY Dolphin crash

EY has had a Dolphin crash. I'm restarting the models.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 22:58, Saturday 05 January 2019 (46250)

I've opened FRS12076

david.barker@LIGO.ORG - 11:32, Monday 07 January 2019 (46257)

I took dolphin diagnostics before restarting. comparing Sat 5 Jan with Tue 25 Dec scans shows that an error appeared on h1iscey in this case.

## h1iscey #####################################################
8c8
< Date   : Sat Jan  5 21:39:45 PST 2019
---
> Date   : Tue Dec 25 10:07:36 PST 2018
44c44
<             Link 0 uptime              : 3982458 seconds
---
>             Link 0 uptime              : 2995486 seconds
56c56
<             Chip temperature           : 77 C
---
>             Chip temperature           : 75 C
102,135d101
< ****************  PCIe SLOT ERROR INFORMATION FOR ADAPTER NO 0  ****************
<
<    NACK error cnt - PCIe Slot .................... : 1
<        NACK DLLP transmitted ......................: 1
<        NACK DLLP received .........................: 0
<
<    Total uncorrectable error cnt - PCIe Slot ..... : 0
<        dlperr cnt ................................ : 0
<        sdoenerr cnt .............................. : 0
<        poisoned cnt .............................. : 0
<        fcperr cnt ................................ : 0
<        compto cnt ................................ : 0
<        cabort cnt ................................ : 0
<        uecomp cnt ................................ : 0
<        rcvovr cnt ................................ : 0
<        malformed cnt ............................. : 0
<        ecrc_cnt .................................. : 0
<        ur_cnt .................................... : 0
<        acsv_cnt .................................. : 0
<        uie_cnt ................................... : 0
<        mcblktlp cnt .............................. : 0
<        atopeb cnt ................................ : 0
<        tlppbe cnt ................................ : 0
<
<    Total correctable error cnt - PCIe Slot ....... : 1
<        rcverr cnt ................................ : 1
<        badtlp cnt ................................ : 1
<        baddllp cnt ............................... : 1
<        rplyrovr cnt .............................. : 0
<        rplyto cnt ................................ : 0
<        advisorynf cnt ............................ : 0
<        cie cnt ................................... : 0
<        hlo cnt ................................... : 0
<

 

Displaying report 1-1 of 1.