Displaying report 1-1 of 1.
Reports until 12:57, Tuesday 08 January 2019
H1 General
edmond.merilh@LIGO.ORG - posted 12:57, Tuesday 08 January 2019 - last comment - 09:33, Wednesday 09 January 2019(46286)
Temporary TTFSS Chassis Installed at ISCT6

A temporary FSS chassis (S1812014) was installed on ISCT6. I connected the +/- 18VDC to the chassis as well and left it powered that way. The accompanying +/- HV power supplies were placed on the floor inside the squeezer rack and connected to the chassis. The HV supplies were set to 180VDC as per their counterparts in the CER mezzanine and then turned off until they're needed. WP#8029

Images attached to this report
Comments related to this report
daniel.sigg@LIGO.ORG - 09:33, Wednesday 09 January 2019 (46311)

We need a PFD not a DEMOD for the alternative locking scheme. The bottom unit is already a DEMOD. Will swap.

Displaying report 1-1 of 1.