Dolphin diagnostics differences before/after today's EEPROM change (left chevron after, right chevron before)

< Date   : Tue Jan  8 13:24:38 PST 2019

> Date   : Tue Jan  8 09:43:36 PST 2019

 

<             EEPROM version             : 97  

>             EEPROM version             : 08  

 

<             EEPROM development ver     : 1  

 

<             Topology Autodetect        : No

>             Topology Autodetect        : Yes

 

<             PCIe slot state            : x8, Gen1 (2.5 GT/s) 

>             PCIe slot state            : x8, Gen2 (5 GT/s) 

 

<             Link 0 uptime              : 11585 seconds

>             Link 0 uptime              : 4218828 seconds

 

<             Link 0 state               : x8, Gen1 (2.5 GT/s) 

<             Link 0 required            : x8, Gen1 (2.5 GT/s)

<             Link 0 capabilities        : x8, Gen1 (2.5 GT/s)

>             Link 0 state               : x8, Gen2 (5 GT/s) 

>             Link 0 required            : x8, Gen2 (5 GT/s)

>             Link 0 capabilities        : x8, Gen2 (5 GT/s)

 

< [WARN] IXH Adapter 0 - PCIe slot link speed is only Gen1 

< ==> Local adapter 0 has 1 warnings.

 

Displaying report 1-1 of 1.