Reports until 00:01, Thursday 10 January 2019
H1 ISC
sheila.dwyer@LIGO.ORG - posted 00:01, Thursday 10 January 2019 - last comment - 00:29, Thursday 10 January 2019(46329)
switching DARM control to ETMX reduces scattering shelves, locking notes

Laura Nutall, Georgia, Craig, Sheila, Stefan, Thomas, Danny

Laura pointed out this alog from Valera 42651, based on this we decided to try switching the upper stages of DARM control from ETMY to ETMX.  The attached script should do the switch, some of these things need to be added to the guardian before we try to use the use_ETMX flag to go to ETMX.  The attached screenshot (and template) show the measurement from L2 excitation to DARM for both test masses once we set up the actuation path.  We haven't seen fringe wrapping since making the switch at 6:30 UTC.  Craig has been updating the calibration, which is why our range has been changing. 

Locking notes from earlier today:

 

Images attached to this report
Non-image files attached to this report
Comments related to this report
georgia.mansell@LIGO.ORG - 00:29, Thursday 10 January 2019 (46331)

Here's a quick spectrogram from when Sheila switched DARM control from ETMY to ETMX.

  • The swept sines from ~200 - 600 s are injections.
  • At ~900s the DARM control (L1 and L2) are switched from ETMY to ETMX.
  • At around 1000s the calibration line at 35 Hz is turned back on.
  • The fringe wrapping (extra broadband noise in the 20-50 Hz band that comes and goes) is much reduced when ETMX is the actuator for DARM control.
Images attached to this comment