Reports until 03:53, Thursday 10 January 2019
H1 ISC (ISC)
craig.cahillane@LIGO.ORG - posted 03:53, Thursday 10 January 2019 - last comment - 09:59, Thursday 10 January 2019(46333)
Unable to lock ALS DIFF #EOM


			
			
Comments related to this report
stefan.ballmer@LIGO.ORG - 09:59, Thursday 10 January 2019 (46335)

The problem was a left-on switch on ETMX:  H1:SUS-ETMX_L2_LOCK_OUTSW_L was left on.

The DOWN state now sets this.