Displaying report 1-1 of 1.
Reports until 11:46, Thursday 19 April 2018
LHO VE
kyle.ryan@LIGO.ORG - posted 11:46, Thursday 19 April 2018 - last comment - 12:09, Thursday 10 January 2019(41544)
Leak tested Chevron Baffle nipple @ IP12 location (X-end)
Helium leak tested nipple-to-GV 16.5" joint as well as nipple welds with background of 2 x 10-9 torr*L/sec -> OK.  Currently there is a zero-length reducer with a 1 1/2" valve installed in place of the nominal 2500 L/sec ion pump which has been removed and is being refurbished.  
Comments related to this report
stephen.appert@LIGO.ORG - 12:09, Thursday 10 January 2019 (46338)

Leak testing related to install from aLOG 41523

Baffle nipple/housing is SN006. Chevron baffle assembly is SN004.