MC3 Spectra
Mark B.

Set MC3 to undamped at 08:55 for a 20 minute spectrum series. (We already have a nice damped interval from last night).
Comments related to this report
mark.barton@LIGO.ORG - 09:28, Thursday 08 November 2012 (4637)
Mark B.

Damping restored at 9:25. Data analysis is underway, but the TFs from yesterday were clean and no problems are expected, so the MC3 is released for install.
mark.barton@LIGO.ORG - 10:34, Tuesday 13 November 2012 (4652)
Mark B.

(This comment lingered in draft state for a week because I was hoping to be able to post plots, but plothsts_spectra.m has been crashing at the point where windowing is applied so I'm posting the GPS times so Stuart can have a look.)

Damping on: 
tconvert nov 8 2012 08:00 pst
1036425616

Damping off:
tconvert nov 8 2012 08:56 pst
1036428976