Transmitted Power Comparison

A direct comparison between the transmitted arm powers between O2 and now. The input power during O2 (8/1/2017) was 28W, whereas it is 30W now.

ETM Transmission
Mirror O2 Now Change
ETMX 3.6 ppm 3.9 ppm +8%
ETMY 3.6 ppm 3.8 ppm +6%

The errors for the transmission coefficients are listed as ±0.2 ppm.

Transmission QPD Sum
Channel O2 Now Change Corrected
for
Transmission
H1:ASC–X_TR_A_NSUM      106k      147k 1.38 1.28
H1:ASC–X_TR_B_NSUM 141k 194k 1.38 1.27
H1:ASC–Y_TR_A_NSUM 144K 211k 1.47 1.39
H1:ASC–Y_TR_B_NSUM 153K 225k 1.47 1.39

The average power increase between the two arm cavities is 1.33. Or a factor of 1.24, if corrected for the input power. This isn't compatible with our observed increase in the power recycling gain by factor of about 1.5 (from ~30 to ~45). There is also a fairly large imbalance between the two arms, indicating there may be an inaccuracy in the optical transmission data? or?