Sheila, Georgia, Craig, Koji

We changed the ETMX ESD bias back to 430 V, because we have been having many of the glitches that saturate the ESD drive, and also some locklosses where we were running out of range on the ETMX ESD.  Before this change the RMS was approaching 2e4 counts (we have a 20 bit DAC), but now it is about 1e5. This is undoing the change in 45193

After this change we went to the calibration measurement guardian state and started actuation sweeps.  They have been saved in the calibration SVN.  

Comments related to this report
jeffrey.kissel@LIGO.ORG - 10:09, Tuesday 15 January 2019 (46422)
I've exported and committed the above mentioned actuator sweep measurements. Thanks all!!

The files live here:
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O3/H1/Measurements/FullIFOActuationTFs/
         2019-01-14_H1SUSETMX_L1_iEXC2DARM_25min.xml
         2019-01-14_H1SUSETMX_L1_PCAL2DARM_8min.xml

         2019-01-14_H1SUSETMX_L2_iEXC2DARM_17min.xml
         2019-01-14_H1SUSETMX_L2_PCAL2DARM_8min.xml

         2019-01-14_H1SUSETMX_L3_iEXC2DARM_8min.xml
         2019-01-14_H1SUSETMX_L3_PCAL2DARM_8min.xml