h1asc and adcparser, parts array needs to be even bigger

A few weeks ago I noticed my daily build was reporting adcparser errors with h1asc. The parts array was of fixed size=5000 and h1asc had grown to about 5200 parts. I increased the limit to 6000.

Yesterday I noticed the error had come back, and sure enough h1asc had grown to 6894 parts. As a side note, this seems to be a rather large increase in a short amount of time.

I have bumped up the limit from 6000 to 10,000

Comments related to this report
jenne.driggers@LIGO.ORG - 15:03, Tuesday 15 January 2019 (46439)

I'd never heard of this parts limit before.  The smooth limiters (which have now been put in on the inputs of the ADS servos, since we're using them as part of the ASC system more now) have about 100 parts per limiter.  There are 10 each of pitch and yaw loops in the ADS system, so today I added about 100*20 = 2000 parts (if you count "GoTo" and "From" flags, and mux and demux all as individual parts).  This work was done as part of WP 8047

Since we were booting the ASC model anyway for this work, Keita pulled all of the ODC parts out of the ASC model.