Found a couple of minor Timing System MEDM issues, fixed one (needs SVN commit)

Yasmeen Asali, Dave Barker, Jamie Rollins

We found two problems with the Timing System MEDM screens:

  1. Yasmeen noticed that the Timing Master in READONLY mode will not display any of the fiber ports at the bottom. In EXPERT mode, the ports do display. Strangely, this is not a problem on the RemoteMEDM viewer. This should probably be fixed, though it is not a high priority obviously. Screenshots of one of the differences attached as well as a picture of the READONLY/EXPERT option button.
  2. I noticed that the 1PPS summary pages still had the wrong labels. I fixed this in the MEDM macros but could not SVN commit due to permissions. If you could commit this, I'd appreciate it! (Attempted) commit message below:

Update 1PPS Second Labels in MEDM summary screens

The 1PPS Summary screens, accessible at the bottom of the Timing overview
MEDM screen (SYS_CUST_TIMING.adl), had incorrect descriptions for the
1PPS timing diagnostic signals. The following screens under the summary
button have been fixed:

MSR Comparator/Frequency Counter
CER Comparator/Frequency Counter
EX Comparator/Frequency Counter
EY Comparator/Frequency Counter
--This line, and those below, will be ignored--

M    SYS_CUST_TIMING_MSR_CFC_macro.txt
M    SYS_CUST_TIMING_CER_CFC_macro.txt
M    SYS_CUST_TIMING_XEND_CFC_macro.txt
M    SYS_CUST_TIMING_YEND_CFC_macro.txt

 