Displaying report 1-1 of 1.
Reports until 11:51, Thursday 17 January 2019
H1 CDS (PEM)
david.barker@LIGO.ORG - posted 11:51, Thursday 17 January 2019 - last comment - 14:50, Thursday 17 January 2019(46506)
BRS STS seismometers added to h1pemey, DAQ restarted

The STS seismometer located in the BRS enclosure at EY were added to h1pemey model. They have been top-named to retain their ISI subsystem association. The three channels were added to the DAQ at 256Hz acquisition rate

+: fast channel H1:ISI-GND_STS_ETMY_BRS_ENC_X_OUT_DQ added to the DAQ
+: fast channel H1:ISI-GND_STS_ETMY_BRS_ENC_Y_OUT_DQ added to the DAQ
+: fast channel H1:ISI-GND_STS_ETMY_BRS_ENC_Z_OUT_DQ added to the DAQ


h1pemey and DAQ were restarted.

Comments related to this report
jim.warner@LIGO.ORG - 14:50, Thursday 17 January 2019 (46510)PEM, SEI

These channels are the revived versions of the STS in the BRSY enclosure. Last I check the DOFs for these channels still weren't wired to agree with the ground STS outside the enclosure, but Robert said he would sort that out for me while he was at EY this afternoon. Currently, the BRS_ENC_X is ETMY_Y, BRS_ENC_Y is ETMY_Z and BRS_ENC_Z is ETMY_X, so this data won't be easy to deal with until the wiring gets fixed.