More Bug Fixes in Conditioning / Smoothing of Time Dependent Correction Factors of Calibration
J. Kissel, (and remotely, J. Betzwieser)
WP 8054

Joe had identified some further bugs in the user-developed code that conditions the time-dependent correction factors calculated in front-end calibration pipeline, namely:
 - the median-ing function,
    /opt/rtcds/userapps/release/cds/common/src/BUFFER_AND_MEDIAN.c
 - and the average-ing function,
    /opt/rtcds/userapps/release/cds/common/src/BUFFER_AND_AVERAGE.c
and their calls and parameters inputs to them in the TDEP block of the front-end code library part,
    /opt/rtcds/userapps/release/cal/common/models/CAL_CS_MASTER.mdl

Check out the details in LLO aLOG LLO aLOG 42794.

I've svn up'd the above mentioned codes and part, and have installed them, rebooting the h1calcs model. This did NOT require a DAQ restart. 

Stay tuned for confirmation of goodness (though Joe confirms that things look good at LLO after these changes).