Displaying report 1-1 of 1.
Reports until 15:27, Thursday 17 January 2019
H1 SEI (SEI)
cheryl.vorvick@LIGO.ORG - posted 15:27, Thursday 17 January 2019 (46512)
SEI seismometer mass check - Monthly: FAMIS #8060

For T240s:

Averaging Mass Centering channels for 10 [sec] ...
2019-01-17 15:24:39.368344


There are 5 T240 proof masses out of range ( > 0.3 [V] )!
ETMX T240 1 DOF X/U = 0.357 [V]
ETMX T240 1 DOF Z/W = 0.319 [V]
ETMX T240 2 DOF Y/V = -0.539 [V]
ITMX T240 1 DOF X/U = -0.309 [V]
ITMY T240 3 DOF Z/W = -0.401 [V]


All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 1 DOF Y/V = 0.273 [V]
ETMX T240 2 DOF X/U = -0.191 [V]
ETMX T240 2 DOF Z/W = 0.225 [V]
ETMX T240 3 DOF X/U = 0.262 [V]
ETMX T240 3 DOF Y/V = 0.222 [V]
ETMX T240 3 DOF Z/W = 0.245 [V]
ETMY T240 1 DOF X/U = -0.062 [V]
ETMY T240 1 DOF Y/V = 0.264 [V]
ETMY T240 1 DOF Z/W = -0.021 [V]
ETMY T240 2 DOF X/U = 0.018 [V]
ETMY T240 2 DOF Y/V = -0.059 [V]
ETMY T240 2 DOF Z/W = -0.04 [V]
ETMY T240 3 DOF X/U = -0.032 [V]
ETMY T240 3 DOF Y/V = -0.057 [V]
ETMY T240 3 DOF Z/W = 0.166 [V]
ITMX T240 1 DOF Y/V = 0.119 [V]
ITMX T240 1 DOF Z/W = 0.119 [V]
ITMX T240 2 DOF X/U = 0.147 [V]
ITMX T240 2 DOF Y/V = 0.148 [V]
ITMX T240 2 DOF Z/W = 0.235 [V]
ITMX T240 3 DOF X/U = -0.24 [V]
ITMX T240 3 DOF Y/V = 0.137 [V]
ITMX T240 3 DOF Z/W = 0.033 [V]
ITMY T240 1 DOF X/U = 0.201 [V]
ITMY T240 1 DOF Y/V = 0.142 [V]
ITMY T240 1 DOF Z/W = 0.159 [V]
ITMY T240 2 DOF X/U = 0.174 [V]
ITMY T240 2 DOF Y/V = 0.243 [V]
ITMY T240 2 DOF Z/W = 0.211 [V]
ITMY T240 3 DOF X/U = -0.065 [V]
ITMY T240 3 DOF Y/V = 0.21 [V]
BS T240 1 DOF X/U = -0.001 [V]
BS T240 1 DOF Y/V = -0.086 [V]
BS T240 1 DOF Z/W = 0.256 [V]
BS T240 2 DOF X/U = 0.061 [V]
BS T240 2 DOF Y/V = 0.238 [V]
BS T240 2 DOF Z/W = -0.037 [V]
BS T240 3 DOF X/U = 0.058 [V]
BS T240 3 DOF Y/V = -0.163 [V]
BS T240 3 DOF Z/W = -0.17 [V]


For STSs:

Averaging Mass Centering channels for 10 [sec] ...


2019-01-17 15:26:33.360168
There are 1 STS proof masses out of range ( > 2.0 [V] )!
STS A DOF X/U = -7.959 [V]


All other proof masses are within range ( < 2.0 [V] ):
STS A DOF Y/V = -0.885 [V]
STS A DOF Z/W = -0.314 [V]
STS B DOF X/U = 0.325 [V]
STS B DOF Y/V = 0.373 [V]
STS B DOF Z/W = -0.38 [V]
STS C DOF X/U = 0.314 [V]
STS C DOF Y/V = 0.257 [V]
STS C DOF Z/W = 0.603 [V]
STS EX DOF X/U = -0.077 [V]
STS EX DOF Y/V = 0.298 [V]
STS EX DOF Z/W = 0.236 [V]
STS EY DOF X/U = 0.315 [V]
STS EY DOF Y/V = -0.153 [V]
STS EY DOF Z/W = 0.649 [V]

 

Displaying report 1-1 of 1.