Reports until 09:53, Tuesday 22 January 2019
H1 AOS
edmond.merilh@LIGO.ORG - posted 09:53, Tuesday 22 January 2019 (46568)
PSL Status Report - Weekly FAMIS# 10996

Laser Status:
Front End Power is 32.22W (should be around 30 W)
70W Output Power is 70.5W
Front End Watch is GREEN
70W Watch is GREEN

Laser Status:
Front End Power is 32.22W (should be around 30 W)
70W Output Power is 70.5W
Front End Watch is GREEN
70W Watch is GREEN

PMC:
It has been locked 5 days, 2 hr 55 minutes (should be days/weeks)
Reflected power = 10.53Watts
Transmitted power = 54.47Watts
PowerSum = 65.0Watts.

FSS:
It has been locked for 0 days 1 hr and 34 min (should be days/weeks)
TPD[V] = 3.202V (min 0.9V)

ISS:
The diffracted power is around 2.3%
Last saturation event was 0 days 3 hours and 57 minutes ago (should be days/weeks)


Possible Issues: