Reports until 15:35, Monday 12 November 2012
H1 SUS
mark.barton@LIGO.ORG - posted 15:35, Monday 12 November 2012 - last comment - 23:07, Monday 12 November 2012(4669)
ITMy (QUADTST) TFs
Mark B.

I used DTT to take a set of undamped TFs for M0 and R0 of ITMy (connected up as QUADTST). Screenshots are attached. The graphs look pretty clean.

P.S. Stuart has sent me a set of scripts that has worked recently at LLO but it needed adaptation and I wanted a quick result. I'll try it out this evening, after Jason is done.
Non-image files attached to this report
Comments related to this report
mark.barton@LIGO.ORG - 23:07, Monday 12 November 2012 (4676)
Mark B.

Here are the TFs again in the standard format with model comparisons. (I had to tweak the script to get it to recognize the file names, so I threw up a set of screenshots as a stop gap.)
Non-image files attached to this comment