Displaying report 1-1 of 1.
Reports until 09:37, Wednesday 30 January 2019
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 09:37, Wednesday 30 January 2019 (46705)
CDS maintenance, Tuesday 29th January 2019

Late report for yesterday's light maintenance day.

h1susb123 DAC drive problem

Richard, Dave:

h1iopsusb123 stopped driving its DACs due to a timing glitch. All models on h1susb123 were restarted to clear the problem.

h1sysecatc1plc2sdf unresponsive, restarted

Dave:

Over the weekend I found that h1sysecatc1plc2sdf had become unresponsive. I restarted this 'faux' model on h1ecatmon0 which cleared the problem.

Displaying report 1-1 of 1.